PCR Series Laminar Flow Cabinet

    Provides a high degree of protection
    Designed for installation on standard laboratory benches
    Each unit is factory-tested and certified by an ILCA-MRA-registered laboratory 

Applications

In order to obtain reliable results in clinical and diagnostic PCR work, it is necessary to maintain an ultra-clean work environment that is free from biological and particulate contamination. PCR Laminar Flow Cabinet provide a high degree of protection for products and apparatus in PCR applications. Additionally, UV radiation is needed to destroy post-procedure contaminants. Clyde-Apac

Description

PCR 60 Laminar Flow Cabinet are vertical laminar flow workstations designed for installation on standard laboratory benches, on optional floor stands or trolleys. Their compact dimensions reduce the need for bench space. They are designed and manufactured in the UK, and each unit is factory-tested and certified by a ILAC-MRA-registered laboratory. Please refer to our Services page.

Vertical laminar airflow in the work zone creates a biologically-clean, particle-free work environment that reduces cross contamination during sample preparation.

Partial recirculation of air leaving the work zone reduces air turbulence and extends HEPA filter life.

A short-wavelength UV lamp inactivates residual DNA/RNA particles, thus reducing carryover contamination. The UV operates only with the fan switched off, and the UV shield should be fitted whenever the UV lamp is in use.

PCR60R Cabinets

In addition to the product protection afforded by PCR60 cabinets, the PCR60R series of PCR Laminar Flow Cabinet provides protection for personnel. This is achieved by an air barrier at the work opening and HEPA filtration of the exhaust air.
An air barrier between the operator and the work zone is maintained by a flow of room air into a grille in the work opening. All positive pressure zones are surrounded by negative pressure zones, so as to contain hazardous aerosols.

  • Germicidal UV lamp and safety shield
  • Glare-free fluorescent lighting
  • Low voltage touch controls
  • Easy to clean stainless steel work area
  • Airflow alarm (PCR60R)
  • Comprehensive operation and maintenance manual
  • Made in the UK with 2 year warranty
  • Hourmeter
  • Manometer
  • Power Outlet
  • Service taps for air, gas and vacuum
  • Floor Stand Fixed Height or Electronically Adjustable
  • Trolley
  • Fumigation Adaptors (PCR60R)

PCR Laminar Flow Cabinet Testing for UK Laboratories

Maintaining the performance of PCR Laminar Flow Cabinets is essential to protect sensitive molecular biology processes from contamination and ensure reliable results. Our on-site testing and certification service verifies that your PCR workstation provides consistent clean air conditions for DNA/RNA sample preparation. Each visit includes a full cabinet inspection, airflow velocity measurements to confirm stable laminar flow across the work surface, and HEPA filter integrity testing using an aerosol challenge method to detect any leakage. Smoke visualisation tests are also performed to demonstrate smooth airflow and identify any turbulence that could compromise PCR accuracy. Supporting checks on noise, vibration, and lighting ensure the cabinet is safe and practical for routine use in molecular laboratories. On completion, a detailed compliance report is issued in line with UK laboratory safety guidance, giving confidence in the reliability of your PCR results and helping your lab maintain contamination control standards.